PSR-U Series
NFPA / IFC Compliant and UL 2524, second edition, Listed/Certified
PSR-78-9533-U
UL 2524 Listed Second Edition by Underwriters Laboratories as comprehensive solution with an annunciator and ADRF-BBx-U Series battery backups
NFPA 72, NFPA 1221, IFC, and UL codes compliant solutions
Alarming outputs to supervised circuits for Loss of Normal AC Power, Battery Charger Failure, Low Battery Capacity, Donor Antenna Malfunction/Disconnection, Active RF Emitting Device Malfunction, and System Component Malfunction
New integrated wiring compartment with pre-drilled connector holes and terminal blocks for easy installation.
NEMA 4 enclosure for both indoor and outdoor environments
Supports FCC Part 90 Class A narrowband and Class B wideband repeater designations
Up to 95 dB of gain and up to 33 dBm downlink and 30 dBm uplink output power per band
Supports P25 Phase 1/Phase 2 analog and digital systems
PSR-78-9537-U
UL 2524 Listed Second Edition by Underwriters Laboratories as comprehensive solution with an annunciator and ADRF-BBx-U Series battery backups
NFPA 72, NFPA 1221, IFC, and UL codes compliant solutions
Alarming outputs to supervised circuits for Loss of Normal AC Power, Battery Charger Failure, Low Battery Capacity, Donor Antenna Malfunction/Disconnection, Active RF Emitting Device Malfunction, and System Component Malfunction
New integrated wiring compartment with pre-drilled connector holes and terminal blocks for easy installation
NEMA 4 enclosure for both indoor and outdoor environments
Supports FCC Part 90 Class A narrowband and Class B wideband repeater designation
Up to 95 dB of gain and up to 37 dBm downlink and 30 dBm uplink output power per band
Supports P25 Phase 1/Phase 2 analog and digital systems
Download Datasheet
PSR-VU-9537-U
Tested and approved under UL 2524, Second Edition as comprehensive solution including PSR, annunciator and ADRF BBx Series battery backups
NFPA & IFC code compliant
Alarming output to supervised circuits for: antenna, amplifier, AC or DC power supply, battery, and charger failure including oscillation detection with automatic amplifier shutdown routine
NEMA 4 enclosure for both indoor and outdoor environments
Supports up to 1 wideband and up to 8 non-contiguous narrow bands
Supports P25 Phase 1 / Phase 2 analog and digital systems
Download Datasheet
PSR-U-9537-U
Tested and approved under UL 2524, Second Edition as comprehensive solution including PSR, annunciator and ADRF BBx Series battery backups
NFPA & IFC code compliant
Alarming output to supervised circuits for: antenna, amplifier, AC or DC power supply, battery, and charger failure including oscillation detection with automatic amplifier shutdown routine
NEMA 4 enclosure for both indoor and outdoor environments
Supports up to 1 wideband and up to 8 non-contiguous narrow bands
Supports P25 Phase 1 / Phase 2 analog and digital systems
Download Datasheet
ADXV-R-3378P-U
2W Public Safety 700/800 MHz Fiber Remote Unit
Type 4 / NEMA 4
Supports up to 2 PSR-ANN-L annunciators
UL 2524 Certified, Second Edition by Underwriters Laboratories
Download Datasheet
ADRF-BBU-W
Wall mountable battery enclosure with support for 12V, 24V, and 48V configurations
Certified UL 2524, Second Edition by Underwriters Laboratories
NFPA 72-2013, NFPA 1221-2016/2019, NFPA 1225, IFC 2015/2018/2021 code compliant and FirstNet compliant
Support for up to 24-hour runtime and all NFPA / IFC compliant alarms
Increase runtime by putting two units in parallel
ADRF-BBS-U
Tested, approved, and listed to UL 2524, Second Edition by Underwriters Laboratories with PSR-78-9533-U, and PSR-78-9537-U
Includes single cable between battery and DAS / repeater
NFPA and IFC compliant
Increase runtime by adding unit using parallel cable (ADRF-BBX-U-CBL-21P)
Increase voltage by adding unit using series cable (ADRF-BBX-U-CBL-21S)
Available in 12V, 24V, 48V solutions
Optional wall mount kit available ( ADRF-BBS-X-WMK)
New integrated wiring compartment with terminal blocks for easy installation
Download Datasheet
ADRF-BBL-U
Tested, approved, and listed to UL 2524, Second Edition by Underwriters Laboratories with PSR-78-9533-U, and PSR-78-9537-U
Includes single cable between battery and DAS / repeater
NFPA and IFC code compliant with up to 24-hour runtime and battery disconnect alarm
Increase runtime by adding unit using parallel cable (ADRF-BBX-CBL-21P)
Increase voltage by adding unit using series cable (ADRF-BBX-CBL-21S)
Optional wall mount kit available (ADRF-BBL-X-WMK)
New integrated wiring compartment with terminal blocks for easy installation