Toggle navigation
Search..
Login
Industries
Commercial Real Estate
Education
Energy, Power & Utilities
Healthcare
Hospitality
Public Safety
Sports & Entertainment
Transportation
Solutions
DAS Solutions
Repeater Solutions
Antenna Solutions
Components
Partners
My ADRF
Resources
About Us
Industries
Commercial Real Estate
Education
Energy, Power & Utilities
Healthcare
Hospitality
Public Safety
Sports & Entertainment
Transportation
Solutions
DAS Solutions
Repeater Solutions
Antenna Solutions
Components
Partners
My ADRF
Resources
About Us
Contact Us
PSR-U Series
NFPA / IFC Compliant and UL 2524, second edition, Listed/Certified
PSR-78-9533-U
UL 2524 Listed Second Edition by Underwriters Laboratories as comprehensive solution with an annunciator and ADRF-BBx-U Series battery backups
NFPA 72, NFPA 1221, IFC, and UL codes compliant solutions
Alarming outputs to supervised circuits for Loss of Normal AC Power, Battery Charger Failure, Low Battery Capacity, Donor Antenna Malfunction/Disconnection, Active RF Emitting Device Malfunction, and System Component Malfunction
New integrated wiring compartment with pre-drilled connector holes and terminal blocks for easy installation.
NEMA 4 enclosure for both indoor and outdoor environments
Supports FCC Part 90 Class A narrowband and Class B wideband repeater designations
Up to 95 dB of gain and up to 33 dBm downlink and 30 dBm uplink output power per band
Supports P25 Phase 1/Phase 2 analog and digital systems
Download Datasheet
PSR-78-9537-U
UL 2524 Listed Second Edition by Underwriters Laboratories as comprehensive solution with an annunciator and ADRF-BBx-U Series battery backups
NFPA 72, NFPA 1221, IFC, and UL codes compliant solutions
Alarming outputs to supervised circuits for Loss of Normal AC Power, Battery Charger Failure, Low Battery Capacity, Donor Antenna Malfunction/Disconnection, Active RF Emitting Device Malfunction, and System Component Malfunction
New integrated wiring compartment with pre-drilled connector holes and terminal blocks for easy installation
NEMA 4 enclosure for both indoor and outdoor environments
Supports FCC Part 90 Class A narrowband and Class B wideband repeater designation
Up to 95 dB of gain and up to 37 dBm downlink and 30 dBm uplink output power per band
Supports P25 Phase 1/Phase 2 analog and digital systems
Download Datasheet
PSR-VU-9537-U
Tested and approved under UL 2524, Second Edition as comprehensive solution including PSR, annunciator and ADRF BBx Series battery backups
NFPA & IFC code compliant
Alarming output to supervised circuits for: antenna, amplifier, AC or DC power supply, battery, and charger failure including oscillation detection with automatic amplifier shutdown routine
NEMA 4 enclosure for both indoor and outdoor environments
Supports up to 1 wideband and up to 8 non-contiguous narrow bands
Supports P25 Phase 1 / Phase 2 analog and digital systems
Download Datasheet
PSR-U-9537-U
Tested and approved under UL 2524, Second Edition as comprehensive solution including PSR, annunciator and ADRF BBx Series battery backups
NFPA & IFC code compliant
Alarming output to supervised circuits for: antenna, amplifier, AC or DC power supply, battery, and charger failure including oscillation detection with automatic amplifier shutdown routine
NEMA 4 enclosure for both indoor and outdoor environments
Supports up to 1 wideband and up to 8 non-contiguous narrow bands
Supports P25 Phase 1 / Phase 2 analog and digital systems
Download Datasheet
ADXV-R-3378P-U
2W Public Safety 700/800 MHz Fiber Remote Unit
Type 4 / NEMA 4
Supports up to 2 PSR-ANN-L annunciators
UL 2524 Certified, Second Edition by Underwriters Laboratories
Download Datasheet
ADRF-BBU-W
Wall mountable battery enclosure with support for 12V, 24V, and 48V configurations
Certified UL 2524, Second Edition by Underwriters Laboratories
NFPA 72-2013, NFPA 1221-2016/2019, NFPA 1225, IFC 2015/2018/2021 code compliant and FirstNet compliant
Support for up to 24-hour runtime and all NFPA / IFC compliant alarms
Increase runtime by putting two units in parallel
ADRF-BBS-U
Tested, approved, and listed to UL 2524, Second Edition by Underwriters Laboratories with PSR-78-9533-U, and PSR-78-9537-U
Includes single cable between battery and DAS / repeater
NFPA and IFC compliant
Increase runtime by adding unit using parallel cable (ADRF-BBX-U-CBL-21P)
Increase voltage by adding unit using series cable (ADRF-BBX-U-CBL-21S)
Available in 12V, 24V, 48V solutions
Optional wall mount kit available ( ADRF-BBS-X-WMK)
New integrated wiring compartment with terminal blocks for easy installation
Download Datasheet
ADRF-BBL-U
Tested, approved, and listed to UL 2524, Second Edition by Underwriters Laboratories with PSR-78-9533-U, and PSR-78-9537-U
Includes single cable between battery and DAS / repeater
NFPA and IFC code compliant with up to 24-hour runtime and battery disconnect alarm
Increase runtime by adding unit using parallel cable (ADRF-BBX-CBL-21P)
Increase voltage by adding unit using series cable (ADRF-BBX-CBL-21S)
Optional wall mount kit available (ADRF-BBL-X-WMK)
New integrated wiring compartment with terminal blocks for easy installation
Download Datasheet
Need Coverage? Talk to an ADRF Specialist
Schedule a free consultation to learn how ADRF creates strategic solutions tailored to your particular business needs
Thank you! your message has been sent.
First Name
Last name
Company Name
Email Address
Phone Number
State
State
Alabama
Alaska
Arizona
Arkansas
California
Colorado
Connecticut
Delaware
District Of Columbia
Florida
Georgia
Hawaii
Idaho
Illinois
Indiana
Iowa
Kansas
Kentucky
Louisiana
Maine
Maryland
Massachusetts
Michigan
Minnesota
Mississippi
Missouri
Montana
Nebraska
Nevada
New Hampshire
New Jersey
New Mexico
New York
North Carolina
North Dakota
Ohio
Oklahoma
Oregon
Pennsylvania
Rhode Island
South Carolina
South Dakota
Tennessee
Texas
Utah
Vermont
Virginia
Washington
West Virginia
Wisconsin
Wyoming
Message
Lead Source
--None--
Advertisement
Employee Referral
External Referral
Partner
Public Relations
Seminar - Internal
Seminar - Partner
Trade Show
Web
Word of mouth
Other
Web Source:
Talk to a Consultant