top of page
iStock-157428923 Edited Down Reversed.jpg

HOME >> PSR-U1 Series

PSR-U1 Series

The PSR-U1 Series is ADRF's newest digital public safety repeater, designed to protect the lives of first responders and building occupants. PSR-U1 Series is the first line of public safety repeaters Listed/Certified by UL to UL 2524, the Standard for In-building 2-way Emergency Radio Communication Enhancement Systems, second edition.

PSR-78-9533-U-FRT Cropped reduced.png

UL

UL 2524 Certified,

Second Edition 

IFC

IFC Compliant.

NEMA 4 or TYPE 4

Suitable for indoor and outdoor environments

NFPA

NFPA 72 and NFPA 1221

code compliant

PSR-U1 Benefits

PSR-U1 Products

PSR-78-9533-U-FRT Cropped reduced.png

PSR-78-9533-U1

PSR-78-9537-U-FRT Facing Left Cropped Reduced.png

PSR-78-9537-U1

PSR-VU-9537-U-FRT Facing Left.png

PSR-VU-9537-U1

PSR-VU-9537-U-FRT Facing Left.png

PSR-U-9537-U1

PSR-EPO-ENC-FRT.png

PSR-EPO-PKG-U

ADRF-BBU-W-FRT Cropped Reduced.png

ADRF-BBU-W

PSR-78-9533-U-FRT Cropped reduced.png

PSR-78-9533-U1

  • UL 2524 Listed Second Edition by Underwriters Laboratories as comprehensive solution with an annunciator and ADRF-BBx-U Series battery backups

  • NFPA 72, NFPA 1221, IFC, and UL codes compliant solutions

  • Alarming outputs to supervised circuits for Loss of Normal AC Power, Battery Charger Failure, Low Battery Capacity, Donor Antenna Malfunction/Disconnection, Active RF  Emitting Device Malfunction, and System Component Malfunction

  • New integrated wiring compartment with pre-drilled connector holes and terminal blocks for easy installation

  • NEMA 4 enclosure for both indoor and outdoor environments

  • Supports FCC Part 90 Class A narrowband and Class B wideband repeater designations

  • Up to 95 dB of gain and up to 33 dBm downlink and 30 dBm uplink output power per band

  • Supports P25 Phase 1/Phase 2 analog and digital systems

PSR-78-9537-U-FRT Facing Left Cropped Reduced.png

PSR-78-9537-U1

  • UL 2524 Listed Second Edition by Underwriters Laboratories as comprehensive solution with an annunciator and ADRF-BBx-U Series battery backups

  • NFPA 72, NFPA 1221, IFC, and UL codes compliant solutions

  • Alarming outputs to supervised circuits for Loss of Normal AC Power, Battery Charger Failure, Low Battery Capacity, Donor Antenna Malfunction/Disconnection, Active RF  Emitting Device Malfunction, and System Component Malfunction

  • New integrated wiring compartment with pre-drilled connector holes and terminal blocks for easy installation

  • NEMA 4 enclosure for both indoor and outdoor environments

  • Supports FCC Part 90 Class A narrowband and Class B wideband repeater designation

  • Up to 95 dB of gain and up to 37 dBm downlink and 30 dBm uplink output power per band

  • Supports P25 Phase 1/Phase 2 analog and digital systems

ADXV-R-3378P-U

  • 2W Public Safety 700/800 MHz Fiber Remote Unit.

  • Type 4 / NEMA 4.

  • Supports up to 2 PSR-ANN-L annunciators.

  • UL 2524 Certified, Second Edition by Underwriters Laboratories.

PSR-VU-9537-U-FRT Facing Left.png

PSR-VU-9537-U1

  • Tested and approved under UL 2524, Second Edition as a comprehensive solution including the repeater, annunciator, and a battery backup

  • NFPA 72-2013, NFPA 1221-2016/2019, NFPA 1225, and IFC 2015/2018/2021 code compliant
    Alarming output to supervised circuits for: antenna, amplifier, AC or DC power supply, battery, and charger failure including oscillation detection with automatic amplifier shutdown routine

  • Oscillation detection feature with automatic amplifier shutdown routine

  • NEMA 4 enclosure for both indoor and outdoor environments

  • Supports up to 1 wideband and up to 24 non-contiguous narrow bands

PSR-VU-9537-U-FRT Facing Left.png

PSR-U-9537-U1

  • Tested and approved under UL 2524, Second Edition as a comprehensive solution including the repeater, annunciator, and a battery backup

  • NFPA 72-2013, NFPA 1221-2016/2019, NFPA 1225, and IFC 2015/2018/2021 code compliant
    Alarming output to supervised circuits for: antenna, amplifier, AC or DC power supply, battery, and charger failure including oscillation detection with automatic amplifier shutdown routine

  • Oscillation detection feature with automatic amplifier shutdown routine

  • NEMA 4 enclosure for both indoor and outdoor environments

  • Supports up to 1 wideband and up to 24 non-contiguous narrow bands

PSR-VU-9537-U-FRT Facing Left.png

ADRF-BBU-W

  • Wall mountable battery enclosure with support for 12V, 24V, and 48V configurations

  • Certified UL 2524, Second Edition by Underwriters Laboratories

  • NFPA 72-2013, NFPA 1221-2016/2019, NFPA 1225, IFC 2015/2018/2021 code compliant and FirstNet compliant

  • Support for up to 24-hour runtime and all NFPA / IFC compliant alarms

  • Increase runtime by putting two units in parallel

PSR-EPO-ENC-FRT.png

PSR-EPO-PKG-U

  • Emergency Power Off switch compatible with all -U and -U1 Series products

  • Operates on either AC or DC power input

  • IP66 Rated Enclosure

bottom of page