top of page
iStock-157428923_edited.jpg

HOME >> PSR-U Series

PSR-U Series

The PSR-U Series is ADRF's newest digital public safety repeater designed to protect the lives of first responders and building occupants. PSR-U Series is the first line of public safety repeaters Listed/Certified by UL to UL 2524, the Standard for In-building 2-way Emergency Radio Communication Enhancement Systems, second edition.

UL

UL 2524 Certified, Second Edition by Underwriters Laboratories (UL).

IFC

IFC Compliant.

NEMA 4 or TYPE 4

Suitable for both indoor and outdoor environments.

NFPA

NFPA 72 and NFPA 1221 code compliant.

PSR-U Benefits

PSR-U Products

PSR-78-9533-U

PSR-78-9537-U

PSR-VU-9537-U

PSR-U-9537-U

ADRF-BBU-W

ADRF-BBS-U

ADRF-BBL-U

PSR-78-9533-U

  • UL 2524 Listed Second Edition by Underwriters Laboratories as comprehensive solution with an annunciator and ADRF-BBx-U Series battery backups

  • NFPA 72, NFPA 1221, IFC, and UL codes compliant solutions

  • Alarming outputs to supervised circuits for Loss of Normal AC Power, Battery Charger Failure, Low Battery Capacity, Donor Antenna Malfunction/Disconnection, Active RF  Emitting Device Malfunction, and System Component Malfunction

  • New integrated wiring compartment with pre-drilled connector holes and terminal blocks for easy installation

  • NEMA 4 enclosure for both indoor and outdoor environments

  • Supports FCC Part 90 Class A narrowband and Class B wideband repeater designations

  • Up to 95 dB of gain and up to 33 dBm downlink and 30 dBm uplink output power per band

  • Supports P25 Phase 1/Phase 2 analog and digital systems

PSR-78-9537-U

  • UL 2524 Listed Second Edition by Underwriters Laboratories as comprehensive solution with an annunciator and ADRF-BBx-U Series battery backups

  • NFPA 72, NFPA 1221, IFC, and UL codes compliant solutions

  • Alarming outputs to supervised circuits for Loss of Normal AC Power, Battery Charger Failure, Low Battery Capacity, Donor Antenna Malfunction/Disconnection, Active RF  Emitting Device Malfunction, and System Component Malfunction

  • New integrated wiring compartment with pre-drilled connector holes and terminal blocks for easy installation

  • NEMA 4 enclosure for both indoor and outdoor environments

  • Supports FCC Part 90 Class A narrowband and Class B wideband repeater designation

  • Up to 95 dB of gain and up to 37 dBm downlink and 30 dBm uplink output power per band

  • Supports P25 Phase 1/Phase 2 analog and digital systems

PSR-VU-9537-U

  • Tested and approved under UL 2524, Second Edition as comprehensive solution including PSR, annunciator and ADRF BBx Series battery backups

  • NFPA & IFC code compliant

  • Alarming output to supervised circuits for: antenna, amplifier, AC or DC power supply, battery, and charger failure including oscillation detection with automatic amplifier shutdown routine.

  • NEMA 4 enclosure for both indoor and outdoor environments

  • Supports up to 1 wideband and up to 8 non-contiguous narrow bands

  • Supports P25 Phase 1 / Phase 2 analog and digital systems

PSR-U-9537-U

  • Tested and approved under UL 2524, Second Edition as comprehensive solution including PSR, annunciator and ADRF BBx Series battery backups

  • NFPA & IFC code compliant

  • Alarming output to supervised circuits for: antenna, amplifier, AC or DC power supply, battery, and charger failure including oscillation detection with automatic amplifier shutdown routine

  • NEMA 4 enclosure for both indoor and outdoor environments

  • Supports up to 1 wideband and up to 8 non-contiguous narrow bands

  • Supports P25 Phase 1 / Phase 2 analog and digital systems

ADXV-R-3378P-U

  • 2W Public Safety 700/800 MHz Fiber Remote Unit.

  • Type 4 / NEMA 4.

  • Supports up to 2 PSR-ANN-L annunciators.

  • UL 2524 Certified, Second Edition by Underwriters Laboratories.

ADRF-BBU-W

  • Wall mountable battery enclosure with support for 12V, 24V, and 48V configurations.

  • Certified UL 2524, Second Edition by Underwriters Laboratories.

  • NFPA 72-2013, NFPA 1221-2016/2019, NFPA 1225, IFC 2015/2018/2021 code compliant and FirstNet compliant.

  • Support for up to 24-hour runtime and all NFPA / IFC compliant alarms.

  • Increase runtime by putting two units in parallel.

ADRF-BBL-U

  • Tested, approved, and listed to UL 2524, Second Edition by Underwriters Laboratories with PSR-78-9533-U, and PSR-78-9537-U.

  • Includes single cable between battery and DAS / repeater.

  • NFPA and IFC code compliant with up to 24-hour runtime and battery disconnect alarm.

  • Increase runtime by adding unit using parallel cable (ADRF-BBX-CBL-21P).

  • Increase voltage by adding unit using series cable (ADRF-BBX-CBL-21S).

  • Optional wall mount kit available (ADRF-BBL-X-WMK).

  • New integrated wiring compartment with terminal blocks for easy installation.

ADRF-BBS-U

  • Tested, approved, and listed to UL 2524, Second Edition by Underwriters Laboratories with PSR-78-9533-U, and PSR-78-9537-U.

  • Includes single cable between battery and DAS / repeater.

  • NFPA and IFC compliant.

  • Increase runtime by adding unit using parallel cable (ADRF-BBX-U-CBL-21P).

  • Increase voltage by adding unit using series cable (ADRF-BBX-U-CBL-21S).

  • Available in 12V, 24V, 48V solutions.

  • Optional wall mount kit available ( ADRF-BBS-X-WMK).

  • New integrated wiring compartment with terminal blocks for easy installation.

bottom of page